Software-driven Z-axis control with autofocus for repeatable focusing and saved Z positions.
Capture and merge multiple focal planes to extend imaging beyond a single focal plane.
Advanced deconvolution processing helps reduce out-of-focus blur and restore image detail.
Automatic objective magnification detection supports a smoother imaging workflow.
Magic Path Proprietary Infinity-corrected Optical System for optimized light throughput and high-contrast imaging. Redesigned optical path to minimize signal loss in every step making it effective in detection of poor and weak fluorescence signals.
MagicVision (DconEZ) applies deconvolution processing to reduce out-of-focus blur and improve contrast in fluorescence images. This enhancement makes fine structures easier to distinguish, particularly in densely labeled specimens or images affected by background haze. Capture and merge multiple focal planes to extend imaging beyond a single focal plane.
Magic Depth Red’s Z-stack imaging function, captures images at multiple focal planes and merges the in-focus regions into a single extended-depth-of-field image. This provides clearer visualization of thick or uneven specimens that cannot be fully represented within a single focal plane. Advanced deconvolution processing helps reduce out-of-focus blur and restore image detail.
Built-in peak LEDs at 365, 470, 550 and 620 nm.
Merge up to 5 channels: 1 brightfield + 4 fluorescence.
Maximum listed resolution of 4000 × 3000.
Cell counting and fluorescence intensity analysis are included.
| Microscope | Inverted type; infinity-corrected optical system |
|---|---|
| Observation | Brightfield, fluorescence, phase contrast |
| Containers | Culture dish, well plate, slide glass, flask and more |
| Objectives | Lplan Fluor 4×, 10×, 20×, 40× standard; optional 2×, 60×, 100× oil |
| Stage | Manual X-Y travel range: 130 × 90 mm |
| Fluorescence filters | DAPI, FITC, Texas Red, Cy5 |
| Sensor | Built-in low-noise CMOS; max 4000 × 3000 |
| Z control | Auto focus & Z-stack; Z-step resolution 0.1 μm |
Live-Cell Fluorescence Imaging
Weak / Low-Abundance Signals
Multi-Color Immunofluorescence
Cell-Culture Monitoring & QC
Tissue Sections & Thicker Specimens
Education & Core Facilities
Shorter exposure times → higher throughput and reduced phototoxicity.
Clearer images of weak signals; more reliable quantitative analysis.
Instant on/off, stable output, 50,000+ hr lifetime - no mercury handling or alignment.
Reduced training time; accessible to students and multi-user environments.
Saves bench space; suits small labs and multi instrument rooms.
Local Asia-Pacific support; competitive performance vs. traditional Western brands.
Live-Cell Fluorescence Imaging
Live-Cell Fluorescence Imaging
Live-Cell Fluorescence Imaging
Live-Cell Fluorescence Imaging
Live-Cell Fluorescence Imaging
Live-Cell Fluorescence Imaging